| Products |
|
 |
Semi-conductive S/W Tape : DYC Series |
|
|
|

|

|
Click to enlarge image
|
|
Product Structure(Sectional
Diagram)
|
|
Thin Non-woven Fabric |
| POWDER* |
| Thick Non-woven
Fabric |
| *The Composion of Powder |
|
|
Super Absorbent Polymer (Excellent swelling
speed & swelling height) |
|
|
Super Absorbent Polymer (Gel
Strength & Thermostbility) |
|
|
Synthetic Binder |
|
|
Corrosion Inhibitor |
|
| Applicable Cables: |
Power Cable |
|
- Under Neutral Screen Wires |
|
-Under radial water barriers( lead, steel, copper,
Al )jaket |
|
- In between Outer Semi-conductive Layer and Corrugated Alumium
Jaket |
|
Conductor
|
|
|
Inner Semi-conductive Layer
|
|
|
Insulation Layer
|
|
|
Outer Semi-conductive Layer
|
|
|
Semi-conductive S/W
Tape
|
|
|
Neutral Screen Wire
|
|
|
Non-conductive S/W
Tape
|
|
|
Sheath
|
|
|
Specification
Product code
|
Thickness
|
Weight
|
Tensile Strength
|
Elongation
|
Swelling Speed
|
Swelling Height
|
Surface Resistance
|
Volume Resistance
|
Long Term Stabilty
|
Short Term Stabilty
|
|
mm
|
g/m2
|
N/cm
|
%
|
mm/1min
|
mm/3min
|
ohm
|
ohm cm
|
?
|
?
|
|
DYC 350H
|
0.35
|
155
|
49
|
15
|
7
|
17
|
2,000
|
<106
|
90
|
230
|
|
DYC 450L
|
0.45
|
160
|
40
|
15
|
6
|
18
|
2,000
|
<106
|
90
|
230
|
|
DYC 500L
|
0.50
|
170
|
40
|
15
|
6
|
19
|
2,000
|
<106
|
90
|
230
|
|
DYC 500H
|
0.50
|
170
|
40
|
15
|
10
|
20
|
2,000
|
<106
|
90
|
230
|
|
DYC 600H
|
0.60
|
185
|
50
|
15
|
12
|
18
|
2,000
|
<106
|
90
|
230
|
|
|
|
|
| |
|
|
|